Setup Assistants¶
The web app provides four setup assistants for initial configuration. Open them from the web app menu. They write directly to the corresponding settings pages.
Network¶
Configures basic Wi-Fi: SSID (network name) and password.
MQTT¶
Four steps, followed by a summary:
- Activation: Enable or disable MQTT globally.
- Connection: Broker IP, port and MQTT device name.
- Login and topic: Optional username/password and MQTT topic name.
- Publishing: Send interval in seconds.
Serial Interfaces¶
Configure device type and chain length on Serial 0–2. The assistant then automatically fills data-device mapping, creating a device for each specified unit with the appropriate interface and consecutive address.
Inverter¶
Four steps for inverter and basic charge control, followed by a summary:
- Enable CAN and select protocol: Enables BMS CANbus enable, selects the CAN protocol and uses active data devices as sources.
- Basic values: Requests cell count and maximum cell voltage. Calculates absorption voltage (maximum cell voltage × cell count, rounded up to 0.1 V), float voltage (3.37 V × cell count) and float voltage SoC (90 %).
- Cell voltage reduction: Enables charge reduction and sets start cell voltage, float maximum cell voltage and minimum current to established values (3370 mV / 0 A).
- Cell voltage difference reduction: Enables it with start voltage 3400 mV, start difference 20 mV and reduction 2 A per mV.
Only Listed Parameters Are Changed
All other settings remain unchanged and can be adjusted afterwards on their settings pages.