Discharging

Configure discharge-current limits based on cell voltage, temperature, temperature profiles and per-pack current. Set pack currents under Inverter / Basic Data / Batterypack Settings. Temperature rules work like their charging equivalents.

Excessive Discharge Current per Pack

Automatically and dynamically adjusts discharge current to keep each battery pack within its configured per-pack discharge limit, protecting against overcurrent.

  • Reduce discharging current if a pack exceeds its discharge-current limit
    • On/Off

Cell-Voltage-Dependent Discharge Reduction

Adjusts discharge current based on cell voltage to protect cells and their service life.

    • On/Off
    • Start below cell voltage
       mV
      Reduction starts when the lowest cell voltage falls below this value.
    • End cell voltage
       mV
      When the lowest cell voltage falls below this value, discharging is limited to the minimum discharging current.
      Note: this value must be below the start cell voltage.
    • Minimum discharging current
       A
  • On/Off: Enables cell-voltage-dependent reduction.
  • Start below cell voltage: Reduction starts when the lowest cell falls below this threshold.
  • End cell voltage: At or below this voltage, current is reduced to the configured minimum.
  • Minimum discharge current: Lower bound used below the end voltage.

Threshold Order

End cell voltage must always be lower than start cell voltage.

Temperature-Dependent Discharge Reduction

Up to 4 individually configurable temperature rules use active data or group sources. Cold-side reduction uses the minimum temperature; hot-side reduction uses the maximum.

  • Uses the sources from the active data source (data devices or group devices).
    Control uses the appropriate extreme for the direction: the minimum temperature when reducing from warm to cold, the maximum when reducing from cold to warm.
    • Temperature rules
    • Rule 1
    • On/Off
    • Data-device sensors
       
    • Extended sensor sources
       
    • Extended sensors 0-31
       
    • Reduction start
       °C
    • Reduction end
       °C
  • Data-device sensors: Sensors 0–5.
  • Extended sources / sensors 0–31: Additional sensors, e.g. OneWire.
  • Reduction start: Temperature where reduction starts, default 20.00 °C.
  • Reduction end: Temperature where current reaches 0 A, default 0.00 °C.

Reduction is linear between thresholds and can work for rising or falling temperatures. See the charging examples, which apply analogously.

Temperature-Profile Discharge Reduction

A freely defined 10-point temperature profile assigns a maximum C-rate to each temperature. Interpolate linearly between points; below/above the profile, use its first/last point.

  • Uses the sources from the active data source (data devices or group devices).
    • On/Off
    • Data-device sensors
       
    • Extended sensor sources
       
    • Extended sensors 0-31
       
    • Temperature profile
      -30°C-15°C0°C15°C30°C45°C60°C00.20.40.60.81C
      Show values
      X (°C)Y (C)
      -300
      -200.1
      -100.2
      -50.4
      00.6
      51
      450.5
      500.25
      550.2
      600
  • Data-device sensors: Sensors 0–5 used in control.
  • Extended sources / sensors 0–31: Additional sources such as OneWire.
  • Temperature profile: 10 temperature/C-rate pairs. Temperature range −30 to 60 °C, step 0.1 °C; C-rate step 0.01 C.

Discharge current is C-rate × capacity (Ah) using capacities from Batterypack Settings, capped by the maximum discharge current. With no configured capacity, discharge current is limited to 0 A.