Zum Inhalt

Software Version Comparison

A quick overview of what you get with the Free Version versus the Sponsor Version.
The sponsored version offers you the latest features, advanced control functions, and a modern user interface – ideal for those who always want the newest features.

Feature Free Version Sponsor Version

Web Interface
Modern Web Application
A fast, modern, feature-rich web app for configuring and managing the system
Extended Dashbaord
Advanced dashboard with rich insights like live charging control data and data-device information
Web Interface Dark Mode
Standart Webapplikation
A simple but functional web app for the system configuration
Standart Dashbaord
A lightweight dashboard showing the most important key metrics
Login screen with Autologout
Basic Web Authentication

General
Wi-Fi Reconnect
If the connection to the access point is lost, the system will periodically retry and restore it automatically
MQTT
REST-API
Settings Export & Import
Maintenance Mode
Temporarily exclude individual battery packs from control and monitoring for service or troubleshooting

Inverter / General
Data Sources
Define which devices provide the data that is sent to the inverter
Aggregation SoC
Advanced selection and weighting of devices for calculating state of charge
Aggregation Total Voltage
Advanced selection and weighting of devices for calculating overall voltage
Aggregation Total Current
Advanced selection and weighting of devices for calculating overall current
Battery Temperature Sensors
Manual selection of sensors used for battery temperature
Cell Temperature Sensors
Manual selection of sensors used for cell temperature
Charging voltage ramp
Define how quickly charging voltage changes (voltage/time ramp) when adjustments are needed

Inverter / Charge Control
Maximum device current
Note: In the Sponsor Version the limit is defined by the inverter’s CAN protocol — not by the BSC
320 A 3200 A
Dynamic charge voltage offset
Reduce charging current - temperature
Reduce charging current - temperature profile
Voltage regulation for current zero control
Charging current per pack too high
Sponsor Version: can additionally use current calculated from C-rate and temperature as a control basis
Autobalance
Sponsor Version includes additional advanced options
Throttle the charging current depending on the cell voltage
Reduce charging current in case of cell drift
Reduce charging current - SoC
Charging current Cut-Off
Set SoC when the cell voltage falls below
Discharging current per pack too high
Throttling the discharge current depending on the cell voltage

Alarm Rules / Plausibility Check
Plausibility check
Value comparison

Alarm Rules / BMS
No data from BMS
Voltage monitoring cell min/max
Voltage monitoring battery pack min/max

Alarm Rules / Temperature
Sensor error alarm (Onewire)
Temperature monitoring

Triggers
Trigger Übersicht
Overview of all configured triggers currently in use
Trigger Scheduler
Activate triggers on a time schedule
Trigger on SoC
Activate a trigger when a defined SoC threshold is reached

Legend

Symbol Meaning
Included
Limited